368 research outputs found

    Relevance of tissue Doppler in the quantification of stress echocardiography for the detection of myocardial ischemia in clinical practice

    Get PDF
    In the present article we review the main published data on the application of Tissue Doppler Imaging (TDI) to stress echocardiography for the detection of myocardial ischemia. TDI has been applied to stress echocardiography in order to overcome the limitations of visual analysis for myocardial ischemia. The introduction of a new technology for clinical routine use should pass through the different phases of scientific assessment from feasibility studies to large multicenter studies, from efficacy to effectiveness studies. Nonetheless the pro-technology bias plays a major role in medicine and expensive and sophisticated techniques are accepted before their real usefulness and incremental value to the available ones is assessed. Apparently, TDI is not exempted by this approach : its applications are not substantiated by strong and sound results. Nonetheless, conventional stress echocardiography for myocardial ischemia detection is heavily criticized on the basis of its subjectivity. Stress echocardiography has a long lasting history and the evidence collected over 20 years positioned it as an established tool for the detection and prognostication of coronary artery disease. The quantitative assessment of myocardial ischemia remains a scientific challenge and a clinical goal but time has not come for these newer ultrasonographic techniques which should be restricted to research laboratories

    Strain and strain rate parametric imaging. A new method for post processing to 3-/4-dimensional images from three standard apical planes. Preliminary data on feasibility, artefact and regional dyssynergy visualisation

    Get PDF
    BACKGROUND: We describe a method for 3-/4D reconstruction of tissue Doppler data from three standard apical planes, post processing to derived data of strain rate / strain and parametric colour imaging of the data. The data can be displayed as M-mode arrays from all six walls, Bull's eye projection and a 3D surface figure that can be scrolled and rotated. Numerical data and waveforms can be re-extracted. METHODS: Feasibility was tested by Strain Rate Imaging in 6 normal subjects and 6 patients with acute myocardial infarction. Reverberation artefacts and dyssynergy was identified by colour images. End systolic strain, peak systolic and mid systolic strain rate were measured. RESULTS: Infarcts were visualised in all patients by colour imaging of mid systolic strain rate, end systolic strain and post systolic shortening by strain rate. Reverberation artefacts were visible in 3 of 6 normals, and 2 of 6 patients, and were identified both on bull's eye and M-mode display, but influenced quantitative measurement. Peak systolic strain rate was in controls minimum -1.11, maximum -0.89 and in patients minimum -1.66, maximum 0.02 (p = 0.04). Mid systolic strain rate and end systolic strain did not separate the groups significantly. CONCLUSION: 3-/4D reconstruction and colour display is feasible, allowing quick visual identification of infarcts and artefacts, as well as extension of area of post systolic shortening. Strain rate is better suited to colour parametric display than strain

    Microbial community characterization during anaerobic digestion of Scenedesmus spp. under mesophilic and thermophilic conditions

    Full text link
    [EN] Microbial communities were thoroughly characterized in a mesophilic anaerobic membrane bioreactor (AnMBR) and a thermophilic continuous stirred tank reactor (CSTR), which were both treating recalcitrant microalgal biomass dominated by Scenedesmus. 16S rRNA amplicon sequencing analysis was performed when the AnMBR achieved 70% algal biodegradation and revealed high microbial diversity, probably due to the high solid retention time (SRT) of the AnMBR configuration. The bacterial community consisted of Chloroflexi (27.9%), WWE1 (19.0%) and Proteobacteria (15.4%) as the major phyla, followed by Spirochaetes (7.7%), Bacteroidetes (5.9%) and Firmicutes (3.6%). These phyla are known to exhibit proteolytic and cellulolytic capabilities required to degrade the Scenedesmus cell-wall. Methanosaeta was the most abundant methanogen detected in the AnMBR suggesting that methane was mainly produced by the acetoclastic pathway. In comparison, the thermophilic CSTR achieved 32.6% algal biodegradation, and its bacterial community had fewer Operational Taxonomic Units (977 OTUs) than the AnMBR (1396 OTUs), as is generally observed for high temperature biogas reactors. However, phyla with high hydrolytic potential were detected such as Firmicutes (34.6%) and the candidate taxon EM3 (38.7%) in the thermophilic CSTR. Although the functional metabolism of EM3 in anaerobic digesters is unknown, the high abundance of EM3 suggests that this taxon plays an important role in the thermophilic, anaerobic degradation of Scenedesmus. The abundant syntrophic bacteria and the detection of hydrogenotrophic methanogens in the thermophilic CSTR suggest that the hydrogenotrophic pathway was the dominant pathway for methane production in this reactor.This research has been supported by the Spanish Ministry of Economy and Competitiveness (MINECO, Project CTM2011-28595-C02-01/02), which is gratefully acknowledged. Support from The Research Council of Norway, grant number 228747 (BiogGasFuel), is also appreciated.Greses-Huerta, S.; Gaby, JC.; Aguado García, D.; Ferrer, J.; Seco Torrecillas, A.; Horn, SJ. (2017). Microbial community characterization during anaerobic digestion of Scenedesmus spp. under mesophilic and thermophilic conditions. Algal Research. 27:121-130. https://doi.org/10.1016/j.algal.2017.09.002S1211302

    Evaluation of Microbubbles as Contrast Agents for Ultrasonography and Magnetic Resonance Imaging

    Get PDF
    Background: Microbubbles (MBs) can serve as an ultrasound contrast agent, and has the potential for magnetic resonance imaging (MRI). Due to the relatively low effect of MBs on MRI, it is necessary to develop new MBs that are more suitable for MRI. In this study, we evaluate the properties of SonoVueH and custom-made Fe 3O 4-nanoparticle-embedded microbubbles (Fe3O4-MBs) in terms of contrast agents for ultrsonography (US) and MRI. Methodology/Principal Findings: A total of 20 HepG2 subcutaneous-tumor-bearing nude mice were randomly assigned to 2 groups (i.e., n = 10 mice each group), one for US test and the other for MRI test. Within each group, two tests were performed for each mouse. The contrast agent for the first test is SonoVueH, and the second is Fe 3O 4-MBs. US was performed using a Technos MPX US system (Esaote, Italy) with a contrast-tuned imaging (CnTI TM) mode. MRI was performed using a 7.0T Micro-MRI (PharmaScan, Bruker Biospin GmbH, Germany) with an EPI-T2 * sequence. The data of signal-to-noise ratio (SNR) from the region-of-interest of each US and MR image was calculated by ImageJ (National Institute of Health, USA). In group 1, enhancement of SonoVueH was significantly higher than Fe 3O 4-MBs on US (P,0.001). In group 2, negative enhancement of Fe3O4-MBs was significantly higher than SonoVueH on MRI (P,0.001). The time to peak showed no significant differences between US and MRI, both of which used the same MBs (P.0.05). The SNR analysis of the enhancement process reveals a strong negative correlation in both cases (i.e., SonoVueH r=20.733, Fe 3O 4-MBs r = 20.903

    Tissue Doppler echocardiographic quantification. Comparison to coronary angiography results in Acute Coronary Syndrome patients

    Get PDF
    BACKGROUND: Multiples indices have been described using tissue Doppler imaging (DTI) capabilities. The aim of this study was to assess the capability of one or several regional DTI parameters in separating control from ischemic myocardium. METHODS: Twenty-eight patients with acute myocardial infarction were imaged within 24-hour following an emergent coronary angioplasty. Seventeen controls without any coronary artery or myocardial disease were also explored. Global and regional left ventricular functions were assessed. High frame rate color DTI cineloop recordings were made in apical 4 and 2-chamber for subsequent analysis. Peak velocity during isovolumic contraction time (IVC), ejection time, isovolumic relaxation (IVR) and filling time were measured at the mitral annulus and the basal, mid and apical segments of each of the walls studied as well as peak systolic displacement and peak of strain. RESULTS: DTI-analysis enabled us to discriminate between the 3 populations (controls, inferior and anterior AMI). Even in non-ischemic segments, velocities and displacements were reduced in the 2 AMI populations. Peak systolic displacement was the best parameter to discriminate controls from AMI groups (wall by wall, p was systematically < 0.01). The combination IVC + and IVR< 1 discriminated ischemic from non-ischemic segments with 82% sensitivity and 85% specificity. CONCLUSION: DTI-analysis appears to be valuable in ischemic heart disease assessment. Its clinical impact remains to be established. However this simple index might really help in intensive care unit routine practice

    Electrical and Mechanical Ventricular Activation During Left Bundle Branch Block and Resynchronization

    Get PDF
    Cardiac resynchronization therapy (CRT) aims to treat selected heart failure patients suffering from conduction abnormalities with left bundle branch block (LBBB) as the culprit disease. LBBB remained largely underinvestigated until it became apparent that the amount of response to CRT was heterogeneous and that the therapy and underlying pathology were thus incompletely understood. In this review, current knowledge concerning activation in LBBB and during biventricular pacing will be explored and applied to current CRT practice, highlighting novel ways to better measure and treat the electrical substrate

    Echocardiographic prediction of outcome after cardiac resynchronization therapy: conventional methods and recent developments

    Get PDF
    Echocardiography plays an important role in patient assessment before cardiac resynchronization therapy (CRT) and can monitor many of its mechanical effects in heart failure patients. Encouraged by the highly variable individual response observed in the major CRT trials, echocardiography-based measurements of mechanical dyssynchrony have been extensively investigated with the aim of improving response prediction and CRT delivery. Despite recent setbacks, these techniques have continued to develop in order to overcome some of their initial flaws and limitations. This review discusses the concepts and rationale of the available echocardiographic techniques, highlighting newer quantification methods and discussing some of the unsolved issues that need to be addressed
    corecore